Troubleshooting: Voltage Issues

CAUTION: Do not attempt to service the system except as explained in the documentation. Only trained service technicians should remove the system cover to access any of the internal components. Refer to the documentation for your server for complete safety information before attempting to service your system.

Voltage problems often indicate a problem with the voltage components. To isolate the root cause of a failure of a given voltage, verify that the source of the suspect voltage is functioning properly. For example, if voltage CPU1 Core is failing, verify that its source(s), 12V Main and 5V Main are functioning properly.

Refer to Troubleshooting the VRM Component for more information.

Run the diagnostics tests for voltage modules to locate and diagnose voltage problems.

Several voltages are monitored and tested. Of these, some are directly supplied by the power supply. Most, however, are voltages derived from bulk voltages. For example, some are generated by the point-of-use VRMs associated with CPU0 and CPU1 and their respective memories.

Related Topics

Troubleshooting the Service Processor