Patch-ID# 100919-02 Keywords: scsi driver 424Mb disk drive going offline Synopsis: 4.1.1: scsi disk drive goes offline after a power down cycle Date: May/19/93 SunOS release: 4.1.1 Unbundled Product: Unbundled Release: Topic: scsi disk drive goes offline after a power down cycle BugId's fixed with this patch: 1118826 Architectures for which this patch is available: sun4 Patches which may conflict with this patch: none Obsoleted by: Files included with this patch: Problem Description: When running on-line disk suite which use two mirrors, if you power down the 424Mb Seagate drives and then power it back up, you cannot recover the drive using ODS commands. Also, format is confused as to the drive type and configuration. This problem is only on the drives shipped prior to 1/92. Install Instructions: As root Save the original objects: mv /sys/sun4/OBJ/sd.o /sys/`arch -k`/OBJ/sd.o.FCS Put the new ones: cp 4.1.1/sd.o /sys/`arch -k`/OBJ/sd.o Rerun /etc/config and make and install the new kernel. Please refer to the system and networking administration manual for details on building and installing a new kernel.