Patch-ID# 106164-21 Keywords: SunLink 9.1 SNA GMAN gateway manager Synopsis: SunLink SNA GMAN Gateway Manager, 9.1: Patch 106164-21 Date: Jan/29/2002 Solaris Release: 2.4 2.5 2.5.1 2.6 7 8 SunOS Release: 5.4 5.5 5.5.1 5.6 5.7 5.8 Unbundled Product: SNA GMAN Gateway Manager Unbundled Release: 9.1 Xref: Topic: Relevant Architectures: sparc BugId's fixed with this patch: 4104397 4176429 4194141 4211608 4353450 4431540 4511975 64339711 Changes incorporated in this version: 4511975 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: SUNWgman/BMD/BCPD_msglib SUNWgman/BMD/BLMS_msglib SUNWgman/BMD/BMSG_msglib SUNWgman/BMD/GMAN_msglib SUNWgman/BMD/XSVC_msglib SUNWgman/BMD/XSVC_msglib.temp1 SUNWgman/SunGMAN.rc SUNWgman/aud.awk SUNWgman/audit_filter SUNWgman/bmsg SUNWgman/suncpd SUNWgman/sungman SUNWgman/sungmanmib.txt SUNWgman/sunsetup SUNWgman/BMD/BCFG_msglib Problem Description: revision=21 SUN BUGID: 4511975 SUN ESC: 532413 CNT Product Defect: 1-6K8SF CNT Release: R9.1.0.31 Description: Pacing values under mode directive are set wrong in active file. Fix SndPacing and RcvPacing field in MODE where these two fields are reversely defined in this table. revision=20 SUN BUGID: 64339711 SUN ESC: 532396 CNT Product Defect: 1-6IJO9 CNT Release: R9.1.0.30 Description: GMAN process consumes 96pu on 43 machines. SUN BUGID: 62668626 SUN ESC: 532413 CNT Product Defect: 1-6K8SF CNT Release: R9.1.0.30 Description: Pacing value under mode directive are set wrong in active file. revision=19 SUN BUGID: 4431549 SUN ESC: 529904 CNT Product Defect: 1-46YST CNT Release: R9.1.0.28 Description: Segmentation fault in sungmi when adding or editing tpname revision=18 SUN BUGID: 4353450 SUN ESC: 526834 CNT Product Defect: 1-25NB2 CNT Release: R9.1.0.26 Description: process growing in size (memory leak) revision=17 SUN BUGID: SUN ESC: CNT Product Defect: 1-2TUZ5 CNT Release: R9.1.0.26 Description: allow proper definition of hex TP names revision=16 SUN BUGID: SUN ESC: CNT Product Defect: 1-2FLAU CNT Release: R9.1.0.25 Description: brxgman was not load balancing to correct system. revision=15 SUN BUGID: SUN ESC: CNT PSR: 1-194M5 CNT Release: R9.1.0.24 Description: Change so GMAN won't be able to save invalid config with bad PUs using duplicate SDLC addresses on the same link. SUN BUGID: SUN ESC: CNT PSR: 1-2BUM2 CNT Release: R9.1.0.24 Description: General fixes to not use freed or uninitialized memory and fix potential memory leaks. SUN BUGID: SUN ESC: CNT PSR: 1-12PWL CNT Release: R9.1.0.24 Description: Change so won't optimize code and create bad compiled code. Problem exhibited itself by sometimes hanging GMI when creating several PU's. revision=14 SUN BUGID: SUN ESC: CNT PSR: 1-X6W9 CNT Release: R9.1.0.23 Description: Segment violation in sungamn when starting brxsman process revision=13 SUN BUGID: SUN ESC: 523924 CNT PSR: 37806 CNT Release: R9.1.0.22 Description: GMAN fix to properly fix PSR 28349 so it won't create incorrect configurations which should default to a network name and LU name for NQ_LU_NAME when creating partner definitions. Problme would exhibit itself by putting . as the name and subsequently .NETWORK name. SUN BUGID: SUN ESC: 523924 CNT PSR: 37806 CNT Release: R9.1.0.22 Description: GMAN fix so that checking for duplicate local MAC address won't return an error if the remote MAC and SAP address is different. Check now checks for MAC address pair and associate SAPS now before returning a duplicate error. SUN BUGID: SUN ESC: CNT PSR: 39036 CNT Release: R9.1.0.22 Description: When no brxadmin_pu2 default services port is specified in the configuration PU 2.1 server will no longer default to brxadmin_pu2. This will result in PU 2.1 not getting a socket and LU 6.2 will not be able to connect to PU 2.1. Error messages in PU 2.1 trace will show cmgr_excp_fun: Lost connection to the Connection Manager. The LU 6.2 trace will show cp open failure, retrying messages. THERE IS NO FIX IN THIS PATCH WHICH WAS INTRODUCED IN THE PREVIOUS REVISION 9.1.0.21 PU2.1/GMAN. The workaround is to specify brxadmin_pu2 as the PU2_ADMIN service. revision=12 SUN BUGID: SUN ESC: CNT PSR: 0 CNT Release: R9.1.0.21 Description: Changed compiler optimization to -o2 Added ehhancements as described in /opt/SUNWappc/cpic_lu62mgmt_qllc.html after patch 106723-07 has been installed. revision=11 SUN BUGID: SUN ESC: CNT PSR: 0 CNT Release: R9.1.0.21 Description: Changed compiler optimization to -o2 Merged Enhancement branch Patch Installation Instructions: -------------------------------- Refer to the Install.info file for instructions on using the generic 'installpatch' and 'backoutpatch' scripts provided with each patch. Any other special or non-generic installation instructions should be described below as special instructions. Special Install Instructions: ----------------------------- None. README -- Last modified date: Wednesday, March 27, 2002