Patch-ID# 106513-04 Keywords: A1000 dilbert temperature battery rm6 health_check data corruption Synopsis: RAID Manager 6.1.1: RM6.1.1 status chk, TX chip support, data error Date: Jan/25/2000 NOTE: IMPORTANT ********************************************************************** The revisions 05, 06 and 07 of this patch were BADPATCHed on engineer's request on Nov 2, 2000 Current active patch revision is 04. Reason: This patch has been badpatched since the firmware in the patch, 2.5.6.39.apd, has a known upgrade problem, 4374789, which is fixed in RM 6.22. *********************************************************************** Solaris Release: 2.5.1 2.6 7 SunOS Release: 5.5.1 5.6 5.7 Unbundled Product: RAID Manager Unbundled Release: 6.1.1 NOTE: Update 1 and Update 2 Xref: Topic: Relevant Architectures: sparc BugId's fixed with this patch: 4023075 4094014 4153015 4164090 4180867 4246748 4293936 Changes incorporated in this version: 4293936 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: /usr/lib/osa/README /usr/lib/osa/bin/healthck /usr/lib/osa/bin/recvap /usr/lib/osa/bin/rm6.exec /usr/lib/osa/bin/statap /usr/lib/osa/fw/02050232.apd /usr/lib/osa/fw/02050632.bwd /usr/lib/osa/fw/02050633.apd /usr/lib/osa/fw/fwcompat.def /usr/lib/osa/help/messages.txt /usr/lib/osa/raidcode.txt Problem Description: 4293936 Potential data corruption upon controller failover (from 106513-03) 4246748 RM 6.1.1 needs tx chip firmware, since zx chip shortage (from 106513-02) 4180867 Patch:106513-01 does not install in "RAID Manager 6.1.1" (from 106513-01) 4164090 Status Gui application encounters an unrecoverable error 4153015 RM6.1.1 didn''t display temperature warning status when temp fault led turns on 4094014 RM6.1.1 hardware error A000 after power cycling dilbert 4023075 Health check does not detect battery failure & cache not turned off Patch Installation Instructions: -------------------------------- Refer to the Install.info file for instructions on using the generic ''installpatch'' and ''backoutpatch'' scripts provided with each patch. Any other special or non-generic installation instructions should be described below as special instructions. Special Install Instructions: ----------------------------- If the user is already running 02.05.06.39 firmware 1. We do NOT recommend downgrading to patch 106513-4. See SunAlert SA-24267 which contains a workaround procedure if you run into the firmware problem referenced. 2. You would want to plan for an upgrade to RM6.22 once the upgrade procedure is ready for release. While we do not have a firm target date for the release of this procedure, NWS is working on it with the highest sense of urgency. Again, do not upgrade to RM6.22 except with the to-be-released tested and approved upgrade procedure. This is because the likelihood of running into the firmware problem is very high during upgrade. If you have any question regarding the removal of these patches, or you have an urgent customer situation that requires the fixes in these patches, or your customer needs an immediate upgrade to RM6.22, please follow the normal escalation process. Firmware Update: Once the firmware file is loaded on the host system, the user must manually update the firmware on the StorEdge A1000/A3x00 controller found on each subsystem. This process involves using the RAID Manager application (started by running /usr/lib/osa/bin/rm6). When prompted for the name of the firmware file to use for the controller download, the following firmware file should be specified: 02050633.apd This file will be found in /usr/lib/osa/fw after this patch has been installed. For further details on updating the StorEdge A1000/A3x00 controller firmware, refer to the RAID Manager User''s Guide. This patch should be compatible with the cluster support patch 106707-02 and the Solaris 7 support patch 106552-03. When used in conjunction with patch 106707, the firmware in this patch must be downloaded last.