Patch-ID# 112398-04 Keywords: SunMC U10 SIMMs PCI Synopsis: SunOS 5.1: Sun Management Center 3.0 PU 4 WGS patch Date: Jun/24/2003 Install Requirements: None Solaris Release: 2.5.1 SunOS Release: 5.5.1 Unbundled Product: Sun Management Center Unbundled Release: 3.0 PU4 NOTE: Platform Update 4, RR and GA releases (Build 73) Xref: Topic: Relevant Architectures: sparc BugId's fixed with this patch: 4407106 4532848 4554324 4627180 4765301 4766348 4809968 4815803 Changes incorporated in this version: 4765301 4766348 4809968 4815803 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: /opt/SUNWsymon/addons/SUNWeswga/sbin/es-setup.sh /opt/SUNWsymon/base/lib/sparc-sun-solaris2.5/libcfgsun4uWG.so.1.0 /opt/SUNWsymon/base/lib/sparc-sun-solaris2.5/libconfigdWG.so.1.0 /opt/SUNWsymon/base/lib/sparc-sun-solaris2.5/pkgconfigdWG.so.1.0 /opt/SUNWsymon/base/lib/sparc-sun-solaris2.5/pkgpfaWG.so.1.0 /opt/SUNWsymon/bin/configdWG /opt/SUNWsymon/classes/com/sun/symon/base/modules/Config-Reader4uwg.properties /opt/SUNWsymon/lib/platform/cfg/sunmc_common.conf /opt/SUNWsymon/mdr/modules/cfg/Config-Reader4uwg-d.x /opt/SUNWsymon/mdr/modules/cfg/Config-Reader4uwg-models-d.x /opt/SUNWsymon/mdr/modules/cfg/Config-Reader4uwg-ruletext-d.x /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-d.rul /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-d.x /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-models-d.x /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-ruletext-d.x Problem Description: 4407106 Config reader aborts on U10 with high density SIMMs 4532848 User not able to edit Error Count Attribute in SIMMs table 4554324 Config-Reader does not detect Correctable Memory Errors caused by PCI dvma read 4627180 Module rules parameter shown as base.modules.Config on rcr4u234 rule 4765301 No PV/LV for some WGS-supported machines on console 4766348 Tooltips contain irrelevant info from the actual Hardware icons 4809968 CE message has changed and rcr4u212 regex does not match anymore 4815803 Config-reader does not work correctly on clustered nodes Patch Installation Instructions: -------------------------------- It is recommended that you install patch 103640-40 prior to installing this patch. Refer to the Install.info file for instructions on using the generic 'installpatch' and 'backoutpatch' scripts provided with each patch. Any other special or non-generic installation instructions should be described below as special instructions. Special Install Instructions: ----------------------------- This patch needs to applied to all WGS agent machines in the Sun Management Center environment and to all server machines being used to monitor WGS agents. Please follow the steps below for this patch 1. Stop all Sun Management Center processes using $BASEDIR/SUNWsymon/sbin/es-stop -A ($BASEDIR is the directory where, Sun Management Center has been installed. By default this directory is /opt, thus /opt/SUNWsymon/sbin/es-stop -A) 2. Install this patch as per Patch Installation Instructions 3. Perform this step only on the systems where Sun Management Center Server layer is installed. Run setup of Sun Management Center using $BASEDIR/SUNWsymon/sbin/es-setup ($BASEDIR is the directory where, Sun Management Center has been installed. By default this directory is /opt, thus /opt/SUNWsymon/sbin/es-setup) 4. Start all Sun Management Center processes with, $BASEDIR/SUNWsymon/sbin/es-start -A , by default: /opt/SUNWsymon/sbin/es-start -A README -- Last modified date: Monday, June 2, 2003 README -- Last modified date: Tuesday, June 24, 2003