Patch-ID# 112400-01 Keywords: SunMC U10 SIMMs PCI Synopsis: SunOS 5.7: Sun Management Center 3.0 PU 4 WGS patch Date: Feb/14/2002 Solaris Release: 7 SunOS Release: 5.7 Unbundled Product: Sun Management Center Unbundled Release: 3.0 PU4 NOTE: Platform Update 4, RR and GA releases (Build 73) Xref: Topic: Relevant Architectures: sparc BugId's fixed with this patch: 4407106 4532848 4554324 4627180 Changes incorporated in this version: 4407106 4532848 4554324 4627180 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: /opt/SUNWsymon/base/lib/sparc-sun-solaris2.7/libcfgsun4uWG.so.1.0 /opt/SUNWsymon/base/lib/sparc-sun-solaris2.7/libconfigdWG.so.1.0 /opt/SUNWsymon/base/lib/sparc-sun-solaris2.7/pkgconfigdWG.so.1.0 /opt/SUNWsymon/base/lib/sparc-sun-solaris2.7/pkgpfaWG.so.1.0 /opt/SUNWsymon/bin/configdWG /opt/SUNWsymon/classes/com/sun/symon/base/modules/Config-Reader4uwg.properties /opt/SUNWsymon/mdr/modules/cfg/Config-Reader4uwg-d.x /opt/SUNWsymon/mdr/modules/cfg/Config-Reader4uwg-models-d.x /opt/SUNWsymon/mdr/modules/cfg/Config-Reader4uwg-ruletext-d.x /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-d.rul /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-d.x /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-models-d.x /opt/SUNWsymon/modules/cfg/Config-Reader4uwg-ruletext-d.x Problem Description: 4407106 Config reader aborts on U10 with high density SIMMs 4532848 User not able to edit Error Count Attribute in SIMMs table 4554324 Config-Reader does not detect Correctable Memory Errors caused by PCI dvma read 4627180 Module rules parameter shown as base.modules.Config on rcr4u234 rule Patch Installation Instructions: -------------------------------- Refer to the Install.info file for instructions on using the generic 'installpatch' and 'backoutpatch' scripts provided with each patch. Any other special or non-generic installation instructions should be described below as special instructions. Special Install Instructions: ----------------------------- This patch needs to applied to all WGS agent machines in the Sun Management Center environment and to all server machines being used to monitor WGS agents. Please follow the steps below for this patch 1. Stop all Sun Management Center processes using $BASEDIR/SUNWsymon/sbin/es-stop -A ($BASEDIR is the directory where, Sun Management Center has been installed. By default this directory is /opt, thus /opt/SUNWsymon/sbin/es-stop -A) 2. Install this patch as per Patch Installation Instructions 3. Perform this step only on the systems where Sun Management Center Server layer is installed. Run setup of Sun Management Center using $BASEDIR/SUNWsymon/sbin/es-setup ($BASEDIR is the directory where, Sun Management Center has been installed. By default this directory is /opt, thus /opt/SUNWsymon/sbin/es-setup) 4. Start all Sun Management Center processes with, $BASEDIR/SUNWsymon/sbin/es-start -A , by default: /opt/SUNWsymon/sbin/es-start -A README -- Last modified date: Thursday, February 14, 2002