Patch-ID# 115803-01 Keywords: netbackup 4.5 unix server jni fiber sg.build sgscan Synopsis: NetBackup 4.5 UNIX server JNI fix Date: Aug/18/2003 Install Requirements: None Solaris Release: 2.6 7 8 9 SunOS Release: 5.6 5.7 5.8 5.9 Unbundled Product: Veritas NetBackup Unbundled Release: 4.5 Xref: Topic: Veritas NetBackup 4.5 sg.build and sgscan fix Relevant Architectures: sparc BugId's fixed with this patch: 4867864 Changes incorporated in this version: 4867864 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: 112407-05 or greater Obsoleted by: Files included with this patch: /openv/volmgr/bin/sg.build /openv/volmgr/bin/sgscan Problem Description: 4867864 sg.build does not detect devices attached through jni Patch Installation Instructions: ------------------------------------------------------------------------- Refer to the Install.info file within the patch for instructions on using the generic 'patchadd' and 'patchrm' scripts provided with each patch. Any other special or non-generic installation instructions should be described below. ------------------------------------------------------------------------- Special Install Instructions: As root on the NetBackup Master Server: (for a NetBackup media server, do steps 1-3) 1) Stop the NetBackup and Media Manager daemons: /usr/openv/netbackup/bin/goodies/bp.kill_all 2) Install patched binaries via patchadd. 3) Restart daemons. /usr/openv/netbackup/bin/initbprd /usr/openv/volmgr/bin/ltid -v README -- Last modified date: Monday, August 18, 2003