Patch-ID# 115954-01 Keywords: sun fire 15k sms startup Synopsis: SMS 1.3: sms startup script must be Nordica/Othello+ aware Date: Nov/10/2003 Install Requirements: Reboot after installation Solaris Release: 8 9 SunOS Release: 5.8 5.9 Unbundled Product: System Management Services Unbundled Release: 1.3 Xref: Topic: SMS 1.3: sms startup script must be Nordica/Othello+ aware Relevant Architectures: sparc BugId's fixed with this patch: 4783769 Changes incorporated in this version: 4783769 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: /etc/opt/SUNWSMS/SMS1.3/startup/sms Problem Description: 4783769 The sms startup script, sms, must be Nordica/Othello+ aware for scman1 testing Patch Installation Instructions: -------------------------------- For Solaris 8-9 releases, refer to the man pages for instructions on using 'patchadd' and 'patchrm' scripts provided with Solaris. Any other special or non-generic installation instructions should be described below as special instructions. The following example installs a patch to a standalone machine: example# patchadd /var/spool/patch/104945-02 The following example removes a patch from a standalone system: example# patchrm 104945-02 For additional examples please see the appropriate man pages. See Also: System Management Services (SMS) 1.3 Installation Guide Part No. 816-5320-10 Chapter 4, SMS 1.3 Additional Software Instructions Available at: http://www.sun.com/products-n-solutions/hardware/docs/Servers/High-End_Servers/Sun_Fire_15K/SW_FW_Documentation/SMS/index.html Special Install Instructions: ----------------------------- Follow these steps when installing on the SC: 1. Record which SC is the main SC. 2. Disable failover on MAIN SC (setfailover off). 3. Stop the SMS processes on both SC's simultaneously. /etc/init.d/sms stop 4. Install the patch on both SC's. 5. Start the SMS processes on the previous main SC first. /etc/init.d/sms start 6. After all the sms processes have started (i.e. you're able to run the showenvironment command and get all the system's status), start the SMS processes on the Spare SC next. 7. Enable failover on MAIN SC (setfailover on). OTHELLO+ CP2140 (P/N 501-6754-01) INSTALLATION INSTRUCTIONS: ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ * To support installation of the Othello+ CP2140 controller (P/N 501-6754-01) onto the F12k/F15K System Controller (SC), this SMS startup patch (115954-01) must be installed along with the following required patches (if not already present): 114608-03 (RFE 4822152 = hpost) 114609-02 (RFE 4817832, 4888914 = SSCPOST) 115287-02 (RFE 4783744 = mand) 115776-01 (RFE 4834834, BugId 4797191, 4942949 = SMS flashupdate) 115955-01 (RFE 4736411 = smsconfig) 115957-01 (RFE 4817726, BugId 4896048 = SC OBP) 116087-02 (RFE 4906317 = Solaris8 (point patch see: http://sunsolve.sun.com/point)) Note that these additional patches are NOT required for the Nordica CP1500 (P/N 501-5994-06). For Nordica CP1500, SMS startup patch 115954-01 is "standalone" and forward- and backward-compatible, and therefore is "don't care" in regards to the patch numbers specified above. README -- Last modified date: Monday, November 10, 2003