Patch-ID# 116165-03
Keywords: quantum, tape library, firmware, l25, l100
Synopsis: Hardware, L25/L100 Tape Library, Firmware, V10
Date: Jan/07/2005


Install Requirements: None                      
                      
Solaris Release: 

SunOS Release: 

Unbundled Product: Sun StorEdge L25/L100

Unbundled Release: N/A

Xref: 

Topic: 

Relevant Architectures: 

BugId's fixed with this patch: 5089607

Changes incorporated in this version: 

Patches accumulated and obsoleted by this patch: 

Patches which conflict with this patch: 

Patches required with this patch: 

Obsoleted by: 

Files included with this patch: 

README.116165-03
m4sys_V10-0.b2a

Problem Description:

The library will not remove an expired cleaning tape 
from a Certance drive.
 
Root Cause: The library code expects that a tape will load and come ready.
The Certance drive won't come ready if an expired cleaning tape is inserted.
 
Corrective Action: Modified the library code to work in situations where the 
drive does not come ready.
 
NOTE: The firmware image is common to both L25 and L100 and may be used both.
 
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Contents
--------    
A.0  Firmware File Names, Changes, & Utility Descriptions
B.O  Precautionary Statements
C.O  Patch Installation and Usage Intructions
 
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
A.0  Firmware File Names & Descriptions
---------------------------------------
 A.1 m4sys_v10-0.b2a    --> The firmware binary image V10
 A.2 README.116165-03   --> This file
 
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
B.0  Precautionary Statements
-----------------------------
 
**WARNING:****WARNING:****WARNING:****WARNING:****WARNING:****WARNING:**
 
B.1 The system MUST BE IDLE during the firmware download process!  No 
    other programs should be running while this utility is being used.  
    Failure to do so may cause the devices being upgraded to fail or 
    the system to crash.
 
    Any other computers sharing the same I/O bus as the host system
    must be either disconnected or offline.
 
B.2 If any upgrade failures occur, do not continue upgrading devices.
    For example, loss of power during download will result in damaged
    peripherals and require replacement.
 
    If any failures occur, please collect the following log file:
    "/var/adm/messages", and an explorer dump.  Please forward these 
    files to your service provider for analysis. 
 
B.3 This firmware will only function on a Sun StorEdge L25 or L100 library.
 
B.4 Please READ instructions below completely BEFORE starting download 
    procedure.  Follow the procedures carefully.  You may program 
    stacked library configurations at the same time, however, you may not exit
    the utility until all libraries have completed the download process. 
 
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
C.O  Patch Installation and Usage Intructions
---------------------------------------------
 
C.1 General guidelines for upgrading: 
 
        STOP ALL APPLICATIONS. The system must be idle during the
        firmware upgrade process.
 
        DISCONNECT or take OFFLINE any other computers sharing the same
        I/O bus as the host.
 
        UPGRADE the tape library.  Follow the given instructions in
        the procedure section below.
 
        In case of any disruption or unforeseen events happening on the 
        relevant bus during the firmware download process, it may be 
        that the upgraded device becomes non-functional.  In this event,
        it will be necessary to replace the device. This would happen 
        as a result of an incomplete or corrupted firmware file being 
        downloaded.  Loss of power during the upgrade process would also
        damage the device.
 
**NOTE**    If you cannot upgrade devices due to software application
            interference, try booting off of the Solaris release CD.
 
**NOTE**    After the firmware download is completed, it may be necessary
            to power cycle the device to ensure fully resetting the device.
            In turn, this may also require a successive reboot of the host
            system to ensure all functionality is restored.
 
	REFER TO USER MANUAL for detailed instructions on how to perform this 
	upgrade.
 
C.2 Procedure for Tape library Firmware Download: 
 
Launch the Prism Management console from a Web based browser.
 
The first page that displays when you access the Prism Management Console 
Web pages is the PMC Home page. This page includes information on the library 
status as well as other management pages listed down the left hand side of
the home page.  The library status icon indicates the state of the library by 
two colors. This icon is also a direct link to the library status page. 
 
The colors of the status icon display the following corresponding states:
 
Green: Library is available
Red: Library is unavailable  - this could be due to:
    initializing
    demo running
    diagnostic running (Service mode)
    in Standby or Stop mode
    Unable to communicate with library
 
Accessing another page for the first time from the Home page requires you to
enter a username and password.
 
Note: A default user name (admin) and password (admin) is provided with the 
installation of the Prism Management Card.
 
When the status icon is showing Green, access the Service Operations page.  
In the navigation frame, under Library Management, press Service Operations. 
The management frame displays the Service Operations page 
 
To upload the library firmware:
1. Press Browse to select the V10 firmware image file on the host 
   computer.  The filename will be m4sys_v10-0.b2a
2. Press Upload to begin the library firmware upload.
 
Caution: Before you perform the upload, make sure there are no processes or 
applications accessing the library. If there are, shut down the process or 
application, or pause the operation, until the upload completes.
 
Note: The entire Upload process may take some time if upleveling a multiframe
library. Do not interrupt the process. Wait for the upload to finish. At the 
end of the upload, the library automatically resets itself. During the 
firmware upload process, a progress window is displayed indicating the 
current operation being performed to complete the firmware upload process. 
In a multiframe environment, the master frame is updated first, then 
succeeding frames are updated.
 
After the library is upgraded, the Revision should display 10.0 when checked 
from the OCP of the library.  To check the firmware revision from the OCP of
the library from the home screen select Quickview then select Library.  The
firmware revision will be displayed.
 
PROBLEMS
 
   Any problems regarding this upload by the user following proper 
   procedures should be reported to the user's service provider along
   with the following items:
        1) /var/adm/messages file
        2) explorer dump
 
 
************************************************************************** 
**************************************************************************

Patch Installation Instructions:
-----------------------
None.

Special Install Instructions:
-----------------------
None.

README -- Last modified date:  Friday, January 7, 2005