Patch-ID# 117650-55 NOTE: *********************************************************************** READ THE TERMS OF THE AGREEMENT ("AGREEMENT") IN THE LEGAL_LICENSE.TXT FILE CAREFULLY BEFORE USING THIS SOFTWARE. BY USING THE SOFTWARE, YOU AGREE TO THE TERMS OF THIS AGREEMENT. IF YOU DO NOT AGREE TO ALL OF THE TERMS, PROMPTLY DESTROY THE UNUSED SOFTWARE. *********************************************************************** Keywords: storade storage automated diagnostic environment stortools nwsagent Synopsis: SUNWstade Support patch Date: Dec/05/2005 Install Requirements: NA Solaris Release: 8 9 10 SunOS Release: 5.8 5.9 5.10 Unbundled Product: StorADE Unbundled Release: 2.4 Xref: Topic: Relevant Architectures: sparc BugId's fixed with this patch: 4528540 4632868 4633337 4830507 4834213 4869154 4872593 4888004 4891682 4948042 4956081 4973820 5010374 5015076 5019073 5020701 5020713 5023420 5024702 5024844 5025953 5027700 5038576 5041540 5042759 5042776 5044750 5046998 5047042 5049834 5050444 5050631 5059365 5066214 5066223 5066803 5069458 5069469 5073858 5073925 5074386 5074484 5076817 5077331 5082221 5083977 5086674 5086797 5086897 5087566 5088114 5088800 5088820 5089073 5089074 5089518 5090075 5090749 5091379 5091403 5091436 5096864 5097868 5097874 5098095 5098166 5098542 5099071 5099498 5099545 5099682 5099703 5100301 5100352 5100373 5100487 5102073 5102485 5102580 5102676 5102761 5103207 5103327 5103463 5103529 5103763 5103875 5104243 5105119 5105156 5107115 5107117 5107606 5109535 5109657 5110119 6176518 6178520 6178861 6178890 6179191 6179421 6180517 6181229 6181904 6181927 6182025 6182182 6182538 6182898 6183068 6183366 6183473 6183684 6183685 6183836 6183880 6183904 6183944 6183949 6184142 6184149 6184548 6184579 6184593 6184598 6184617 6184660 6184847 6184884 6184908 6184915 6185548 6186095 6186099 6186215 6186216 6186220 6186248 6188818 6188884 6188967 6188969 6188995 6189010 6189030 6189577 6189655 6190764 6191468 6192123 6192320 6192388 6193443 6193799 6194263 6194312 6194487 6195945 6195986 6196385 6196603 6196693 6196703 6196767 6196832 6197325 6197426 6197980 6198720 6198728 6198837 6198977 6198978 6199419 6201135 6201149 6201208 6201699 6201806 6201830 6201851 6201902 6201928 6201931 6202020 6202066 6202088 6202140 6202601 6203429 6205989 6206014 6206025 6206042 6206051 6206059 6207732 6207850 6208592 6209604 6210245 6210820 6211324 6211766 6211831 6213187 6213749 6213753 6213768 6214268 6214281 6215302 6218992 6219062 6219100 6219107 6219119 6220129 6220130 6220338 6222690 6224004 6224084 6224121 6224261 6224750 6224790 6225221 6225757 6226337 6226712 6226826 6226893 6227289 6227827 6227918 6230572 6231443 6232283 6232290 6232724 6232933 6233330 6233820 6233955 6234026 6234343 6234430 6234504 6234569 6234587 6234639 6235605 6235616 6235630 6235641 6235644 6235701 6235703 6235771 6235777 6235888 6236307 6236409 6236757 6237076 6237820 6237846 6238096 6238299 6238435 6239493 6239831 6241090 6241267 6241804 6241880 6242200 6242338 6242339 6242368 6242419 6243104 6243140 6243154 6243638 6243677 6243722 6243724 6243757 6243777 6243790 6243794 6243805 6243844 6243853 6244035 6244036 6244533 6244536 6244993 6245164 6245385 6245498 6246022 6246505 6246921 6247428 6247437 6248240 6248889 6248912 6248928 6250099 6250240 6250760 6250790 6251009 6252686 6253280 6254179 6254752 6254862 6255377 6255633 6255912 6256377 6257363 6259017 6259327 6259345 6260863 6261887 6262281 6262833 6264160 6264392 6264529 6265274 6265636 6265662 6266257 6267241 6267412 6267808 6267953 6269308 6270508 6271722 6271978 6273339 6273393 6273735 6274753 6274761 6275590 6276708 6278806 6279787 6282743 6283413 6284153 6284177 6284835 6284859 6285522 6286339 6286744 6286820 6287516 6288899 6292949 6293438 6293476 6297014 6297466 6297525 6298454 6298949 6298952 6298957 6299559 6300170 6301718 6303925 6305963 6305976 6306596 6307821 6308361 6308593 6309077 6310574 6310579 6310581 6310587 6310976 6311113 6311166 6311560 6311579 6311880 6311903 6312294 6312331 6313501 6313662 6314284 6314616 6314636 6322839 6326366 6328807 6338483 6345248 6346603 Changes incorporated in this version: 6346603 6345248 6338483 6328807 6326366 6322839 6314636 6314616 6314284 6313662 6313501 6312331 6312294 6311903 6310976 6310587 6310581 6310579 6310574 6308361 6306596 6305976 6299559 6246505 6222690 Patches accumulated and obsoleted by this patch: Patches which conflict with this patch: Patches required with this patch: Obsoleted by: Files included with this patch: /opt/SUNWstade/Diags/bin/a5ksestest /opt/SUNWstade/Diags/bin/brocadetest /opt/SUNWstade/Diags/bin/diagBypassSfp3511 /opt/SUNWstade/Diags/bin/echotest3510 /opt/SUNWstade/Diags/bin/echotest3511 /opt/SUNWstade/Diags/bin/emlxtest /opt/SUNWstade/Diags/bin/jtest /opt/SUNWstade/Diags/bin/linktest /opt/SUNWstade/Diags/bin/loopmap3510 /opt/SUNWstade/Diags/bin/loopmap3511 /opt/SUNWstade/Diags/bin/looptest3510 /opt/SUNWstade/Diags/bin/looptest3511 /opt/SUNWstade/Diags/bin/ondg /opt/SUNWstade/Diags/bin/qlctest /opt/SUNWstade/Diags/bin/se2_configcheck /opt/SUNWstade/Diags/bin/se_configcheck /opt/SUNWstade/Diags/bin/showBypassDevice3510 /opt/SUNWstade/Diags/bin/showBypassDevice3511 /opt/SUNWstade/Diags/bin/showBypassSfp3510 /opt/SUNWstade/Diags/bin/showBypassSfp3511 /opt/SUNWstade/Diags/bin/stresstest /opt/SUNWstade/Diags/bin/switch2test /opt/SUNWstade/Diags/bin/vediag /opt/SUNWstade/Diags/bin/volverify /opt/SUNWstade/Diags/bin/wrbtest3510 /opt/SUNWstade/Diags/bin/wrbtest3511 /opt/SUNWstade/Diags/lib/locale/C/LC_MESSAGES/a5ksestest.msg /opt/SUNWstade/Diags/lib/locale/C/LC_MESSAGES/d2disktest.msg /opt/SUNWstade/Diags/lib/locale/C/LC_MESSAGES/disktest.msg /opt/SUNWstade/Diags/lib/locale/C/LC_MESSAGES/emlxtest.msg /opt/SUNWstade/Diags/lib/locale/C/LC_MESSAGES/fcdisktest.msg /opt/SUNWstade/Diags/lib/locale/C/LC_MESSAGES/qlctest.msg /opt/SUNWstade/Diags/lib/locale/C/LC_MESSAGES/t3test.msg /opt/SUNWstade/Registration/01_activate/activateRS /opt/SUNWstade/Registration/01_activate/listDevicesRS /opt/SUNWstade/Registration/01_activate/run /opt/SUNWstade/Registration/README /opt/SUNWstade/Registration/country_codes.txt /opt/SUNWstade/Registration/install_war_file.txt /opt/SUNWstade/Registration/run /opt/SUNWstade/System/BaseMatrix/config-base /opt/SUNWstade/System/Catalog/common/health.xsd /opt/SUNWstade/System/Catalog/common/implementation.xsd /opt/SUNWstade/System/Catalog/common/model.xsd /opt/SUNWstade/System/Catalog/common/revision.xsd /opt/SUNWstade/System/Catalog/common/std_eventGrid.xml /opt/SUNWstade/System/Catalog/common/std_health.xml /opt/SUNWstade/System/Catalog/common/std_model.properties /opt/SUNWstade/System/Catalog/common/std_model.xml /opt/SUNWstade/System/Catalog/common/storade.xsd /opt/SUNWstade/System/Catalog/device/6130/eventGrid.xml /opt/SUNWstade/System/Catalog/device/6130/health.xml /opt/SUNWstade/System/Catalog/device/6130/implementation.xml /opt/SUNWstade/System/Catalog/device/6130/message.properties /opt/SUNWstade/System/Catalog/device/6130/model.properties /opt/SUNWstade/System/Catalog/device/6130/model.xml /opt/SUNWstade/System/Catalog/device/6130/policies.xml /opt/SUNWstade/System/Catalog/device/6130/revision.xml /opt/SUNWstade/System/Catalog/device/t3/health.xml /opt/SUNWstade/System/Catalog/device/t3/implementation.xml /opt/SUNWstade/System/EGrid/3120jbod.grid /opt/SUNWstade/System/EGrid/3310.grid /opt/SUNWstade/System/EGrid/3310jbod.grid /opt/SUNWstade/System/EGrid/3320.grid /opt/SUNWstade/System/EGrid/3510.grid /opt/SUNWstade/System/EGrid/3511.grid /opt/SUNWstade/System/EGrid/5210.grid /opt/SUNWstade/System/EGrid/5310.grid /opt/SUNWstade/System/EGrid/6020.grid /opt/SUNWstade/System/EGrid/6120.grid /opt/SUNWstade/System/EGrid/6130.grid /opt/SUNWstade/System/EGrid/9900.grid /opt/SUNWstade/System/EGrid/EventGrid2.pdf /opt/SUNWstade/System/EGrid/Grid.idx /opt/SUNWstade/System/EGrid/GridCodes /opt/SUNWstade/System/EGrid/a3500fc.grid /opt/SUNWstade/System/EGrid/a5k.grid /opt/SUNWstade/System/EGrid/agent.grid /opt/SUNWstade/System/EGrid/brocade.grid /opt/SUNWstade/System/EGrid/d2.grid /opt/SUNWstade/System/EGrid/dsp.grid /opt/SUNWstade/System/EGrid/eventlist.txt /opt/SUNWstade/System/EGrid/hbastorage.grid /opt/SUNWstade/System/EGrid/hbaswitch.grid /opt/SUNWstade/System/EGrid/host.grid /opt/SUNWstade/System/EGrid/inrange.grid /opt/SUNWstade/System/EGrid/internal.grid /opt/SUNWstade/System/EGrid/mcdata.grid /opt/SUNWstade/System/EGrid/qlogicsw.grid /opt/SUNWstade/System/EGrid/samfs.grid /opt/SUNWstade/System/EGrid/san.grid /opt/SUNWstade/System/EGrid/se.grid /opt/SUNWstade/System/EGrid/se2.grid /opt/SUNWstade/System/EGrid/service.list /opt/SUNWstade/System/EGrid/solution.include /opt/SUNWstade/System/EGrid/sp.grid /opt/SUNWstade/System/EGrid/sve2.grid /opt/SUNWstade/System/EGrid/switch.grid /opt/SUNWstade/System/EGrid/switch2.grid /opt/SUNWstade/System/EGrid/t3.grid /opt/SUNWstade/System/EGrid/tape.grid /opt/SUNWstade/System/EGrid/topo.grid /opt/SUNWstade/System/EGrid/v880disk.grid /opt/SUNWstade/System/EGrid/ve.grid /opt/SUNWstade/System/Events_1.1.mof /opt/SUNWstade/System/Fault/3120jbod.fault /opt/SUNWstade/System/Fault/3310.fault /opt/SUNWstade/System/Fault/3310jbod.fault /opt/SUNWstade/System/Fault/3320.fault /opt/SUNWstade/System/Fault/3510.fault /opt/SUNWstade/System/Fault/5310.fault /opt/SUNWstade/System/Fault/6130.fault /opt/SUNWstade/System/Fault/array.fault /opt/SUNWstade/System/Fault/dsp.fault /opt/SUNWstade/System/Fault/switch.fault /opt/SUNWstade/System/Fault/z_alldevice.fault /opt/SUNWstade/System/Labels/CommonDesc.lb /opt/SUNWstade/System/Labels/GUI::Passwords.lb /opt/SUNWstade/System/Labels/GUI::Timeouts.lb /opt/SUNWstade/System/Labels/Service::Upgrade.lb /opt/SUNWstade/System/Labels/Trap::5210.lb /opt/SUNWstade/System/Labels/Trap::5310.lb /opt/SUNWstade/System/Labels/global.lb /opt/SUNWstade/System/Map/3120jbod.map /opt/SUNWstade/System/Map/3310.map /opt/SUNWstade/System/Map/3310jbod.map /opt/SUNWstade/System/Map/3320.map /opt/SUNWstade/System/Map/3510.map /opt/SUNWstade/System/Map/3511.map /opt/SUNWstade/System/Map/5210.map /opt/SUNWstade/System/Map/6120.map /opt/SUNWstade/System/Map/6130.map /opt/SUNWstade/System/Map/brocade.map /opt/SUNWstade/System/Map/dsp.map /opt/SUNWstade/System/Map/mcdata.map /opt/SUNWstade/System/Map/qlogicsw.map /opt/SUNWstade/System/Map/se.map /opt/SUNWstade/System/Map/se2.map /opt/SUNWstade/System/Map/switch.map /opt/SUNWstade/System/Map/switch2.map /opt/SUNWstade/System/Map/t3.map /opt/SUNWstade/System/Matrix/config-matrix /opt/SUNWstade/System/Policies/3310_policies /opt/SUNWstade/System/Policies/5210_policies /opt/SUNWstade/System/Policies/Thresholds /opt/SUNWstade/System/Policies/Thresholds.se2 /opt/SUNWstade/System/Policies/array_policies /opt/SUNWstade/System/Policies/dsp_policies /opt/SUNWstade/System/Storage_1.1.mof /opt/SUNWstade/System/Tests/3510.test /opt/SUNWstade/System/Tests/3510oob.test /opt/SUNWstade/System/Tests/3511.test /opt/SUNWstade/System/Tests/3511oob.test /opt/SUNWstade/System/Tests/6120.test /opt/SUNWstade/System/Tests/6120oob.test /opt/SUNWstade/System/Tests/6130.test /opt/SUNWstade/System/Tests/A3500FC.test /opt/SUNWstade/System/Tests/A5K.test /opt/SUNWstade/System/Tests/Brocade.test /opt/SUNWstade/System/Tests/D2.test /opt/SUNWstade/System/Tests/HOST.test /opt/SUNWstade/System/Tests/INT.test /opt/SUNWstade/System/Tests/QLOGICSW.test /opt/SUNWstade/System/Tests/SE.test /opt/SUNWstade/System/Tests/SE2.test /opt/SUNWstade/System/Tests/SE2oob.test /opt/SUNWstade/System/Tests/SWITCH.test /opt/SUNWstade/System/Tests/SWITCH2.test /opt/SUNWstade/System/Tests/T3.test /opt/SUNWstade/System/Tests/T3oob.test /opt/SUNWstade/System/Tests/Tape.test /opt/SUNWstade/System/Tests/V880DISK.test /opt/SUNWstade/System/Tests/VICOM.test /opt/SUNWstade/System/Tests/VICOMoob.test /opt/SUNWstade/System/abbreviations.txt /opt/SUNWstade/System/config /opt/SUNWstade/System/country_codes.txt /opt/SUNWstade/System/exception.conf /opt/SUNWstade/System/pubring.gpg /opt/SUNWstade/System/ras_install.help /opt/SUNWstade/System/trustdb.gpg /opt/SUNWstade/bcrypt-1.1/Makefile /opt/SUNWstade/bcrypt-1.1/README /opt/SUNWstade/bcrypt-1.1/bcrypt.1 /opt/SUNWstade/bcrypt-1.1/blowfish.c /opt/SUNWstade/bcrypt-1.1/blowfish.h /opt/SUNWstade/bcrypt-1.1/config.h /opt/SUNWstade/bcrypt-1.1/defines.h /opt/SUNWstade/bcrypt-1.1/endian.c /opt/SUNWstade/bcrypt-1.1/functions.h /opt/SUNWstade/bcrypt-1.1/includes.h /opt/SUNWstade/bcrypt-1.1/keys.c /opt/SUNWstade/bcrypt-1.1/main.c /opt/SUNWstade/bcrypt-1.1/rwfile.c /opt/SUNWstade/bcrypt-1.1/wrapbf.c /opt/SUNWstade/bcrypt-1.1/wrapzl.c /opt/SUNWstade/bin/6130SupportData /opt/SUNWstade/bin/fix_perl_path /opt/SUNWstade/bin/ras_admin /opt/SUNWstade/bin/ras_downgrade /opt/SUNWstade/bin/ras_install /opt/SUNWstade/bin/ras_install.exe /opt/SUNWstade/bin/ras_patchdowngrade /opt/SUNWstade/bin/ras_patchlist /opt/SUNWstade/bin/ras_revcheck /opt/SUNWstade/bin/ras_upgrade /opt/SUNWstade/bin/rasagent /opt/SUNWstade/bin/rashttp /opt/SUNWstade/bin/sccli /opt/SUNWstade/bin/testdsp /opt/SUNWstade/bin/xfer /opt/SUNWstade/htdocs/Help/dev_discovery.html /opt/SUNWstade/htdocs/Topo/TopoGif/5210x4.gif /opt/SUNWstade/htdocs/Topo/TopoGif/5210x4.png /opt/SUNWstade/htdocs/Topo/TopoGif/5310.gif /opt/SUNWstade/htdocs/Topo/TopoGif/5310.png /opt/SUNWstade/htdocs/Topo/TopoGif/5310x4.gif /opt/SUNWstade/htdocs/Topo/TopoGif/5310x4.png /opt/SUNWstade/htdocs/Topo/TopoGif/6130.gif /opt/SUNWstade/htdocs/Topo/VertexApplet$SymItem.class /opt/SUNWstade/htdocs/Topo/VertexApplet$SymItem2.class /opt/SUNWstade/htdocs/Topo/topo22.jar /opt/SUNWstade/htdocs/copyright.html /opt/SUNWstade/htdocs/copyright2.html /opt/SUNWstade/lib/Agent.pm /opt/SUNWstade/lib/Agent/3310.pm /opt/SUNWstade/lib/Agent/3320.pm /opt/SUNWstade/lib/Agent/5210.pm /opt/SUNWstade/lib/Agent/5310.pm /opt/SUNWstade/lib/Agent/9900.pm /opt/SUNWstade/lib/Agent/A3500FC.pm /opt/SUNWstade/lib/Agent/A5K.pm /opt/SUNWstade/lib/Agent/BROCADE.pm /opt/SUNWstade/lib/Agent/COMMON.pm /opt/SUNWstade/lib/Agent/D2.pm /opt/SUNWstade/lib/Agent/DATAHOST.pm /opt/SUNWstade/lib/Agent/HBASTORAGE.pm /opt/SUNWstade/lib/Agent/HBASWITCH.pm /opt/SUNWstade/lib/Agent/HOST.pm /opt/SUNWstade/lib/Agent/INTERNAL.pm /opt/SUNWstade/lib/Agent/JAVA_Parent.pm /opt/SUNWstade/lib/Agent/MCDATA.pm /opt/SUNWstade/lib/Agent/MESSAGE.pm /opt/SUNWstade/lib/Agent/QLOGICSW.pm /opt/SUNWstade/lib/Agent/SAMFS.pm /opt/SUNWstade/lib/Agent/SE.pm /opt/SUNWstade/lib/Agent/SE_MODULE.pm /opt/SUNWstade/lib/Agent/SLAVE.pm /opt/SUNWstade/lib/Agent/SWITCH.pm /opt/SUNWstade/lib/Agent/SWITCH2.pm /opt/SUNWstade/lib/Agent/T3.pm /opt/SUNWstade/lib/Agent/T3MESSAGE.pm /opt/SUNWstade/lib/Agent/TAPE.pm /opt/SUNWstade/lib/Agent/TRAPMESSAGE.pm /opt/SUNWstade/lib/AutoForm.pm /opt/SUNWstade/lib/CIM/Instance.pm /opt/SUNWstade/lib/COMMON.pm /opt/SUNWstade/lib/Catalog.pm /opt/SUNWstade/lib/Catalog/Diag.pm /opt/SUNWstade/lib/Catalog/Entry.pm /opt/SUNWstade/lib/Catalog/EventGrid.pm /opt/SUNWstade/lib/Catalog/Fault.pm /opt/SUNWstade/lib/Catalog/Grid.pm /opt/SUNWstade/lib/Catalog/Health.pm /opt/SUNWstade/lib/Catalog/HealthConfig.pm /opt/SUNWstade/lib/Catalog/Implementation.pm /opt/SUNWstade/lib/Catalog/Log.pm /opt/SUNWstade/lib/Catalog/Matrix.pm /opt/SUNWstade/lib/Catalog/Message.pm /opt/SUNWstade/lib/Catalog/Model.pm /opt/SUNWstade/lib/Catalog/RF.pm /opt/SUNWstade/lib/Catalog/Register.pm /opt/SUNWstade/lib/Catalog/ReportClass.pm /opt/SUNWstade/lib/Catalog/Revision.pm /opt/SUNWstade/lib/Catalog/Threshold.pm /opt/SUNWstade/lib/Catalog/XML.pm /opt/SUNWstade/lib/Catalog/XmlElment.pm /opt/SUNWstade/lib/Client.pm /opt/SUNWstade/lib/Client/6130Control.pm /opt/SUNWstade/lib/Client/Advisor.pm /opt/SUNWstade/lib/Client/Alarm.pm /opt/SUNWstade/lib/Client/AppLauncher.pm /opt/SUNWstade/lib/Client/Config.pm /opt/SUNWstade/lib/Client/Control.pm /opt/SUNWstade/lib/Client/Device.pm /opt/SUNWstade/lib/Client/Diag.pm /opt/SUNWstade/lib/Client/Diagx.pm /opt/SUNWstade/lib/Client/Discovery.pm /opt/SUNWstade/lib/Client/EventLog.pm /opt/SUNWstade/lib/Client/EventReport.pm /opt/SUNWstade/lib/Client/InstrReport.pm /opt/SUNWstade/lib/Client/Inventory.pm /opt/SUNWstade/lib/Client/Message.pm /opt/SUNWstade/lib/Client/Perf.pm /opt/SUNWstade/lib/Client/ProcMgr.pm /opt/SUNWstade/lib/Client/Revision.pm /opt/SUNWstade/lib/Client/SEControl.pm /opt/SUNWstade/lib/Client/System.pm /opt/SUNWstade/lib/Client/TO.pm /opt/SUNWstade/lib/Client/TestMail.pm /opt/SUNWstade/lib/Client/TestPatchPro.pm /opt/SUNWstade/lib/Client/Upgrade.pm /opt/SUNWstade/lib/Client/VolVerify.pm /opt/SUNWstade/lib/Crypt/DES_PP.pm /opt/SUNWstade/lib/Debug.pm /opt/SUNWstade/lib/DeviceReport.pm /opt/SUNWstade/lib/DeviceReport/3310.pm /opt/SUNWstade/lib/DeviceReport/3320.pm /opt/SUNWstade/lib/DeviceReport/5210.pm /opt/SUNWstade/lib/DeviceReport/5310.pm /opt/SUNWstade/lib/DeviceReport/9900.pm /opt/SUNWstade/lib/DeviceReport/A5K.pm /opt/SUNWstade/lib/DeviceReport/BROCADE.pm /opt/SUNWstade/lib/DeviceReport/COMMON.pm /opt/SUNWstade/lib/DeviceReport/D2.pm /opt/SUNWstade/lib/DeviceReport/HBASTORAGE.pm /opt/SUNWstade/lib/DeviceReport/HBASWITCH.pm /opt/SUNWstade/lib/DeviceReport/HOST.pm /opt/SUNWstade/lib/DeviceReport/MCDATA.pm /opt/SUNWstade/lib/DeviceReport/QLOGICSW.pm /opt/SUNWstade/lib/DeviceReport/SE.pm /opt/SUNWstade/lib/DeviceReport/SP.pm /opt/SUNWstade/lib/DeviceReport/SWITCH.pm /opt/SUNWstade/lib/DeviceReport/SWITCH2.pm /opt/SUNWstade/lib/DeviceReport/T3.pm /opt/SUNWstade/lib/Diag.pm /opt/SUNWstade/lib/Diags/MinnowUtil.pm /opt/SUNWstade/lib/Diags/T3Connection.pm /opt/SUNWstade/lib/Discman.pm /opt/SUNWstade/lib/Discover.pm /opt/SUNWstade/lib/Discover/3310.pm /opt/SUNWstade/lib/Discover/5210.pm /opt/SUNWstade/lib/Discover/5310.pm /opt/SUNWstade/lib/Discover/A3500FC.pm /opt/SUNWstade/lib/Discover/Brocade.pm /opt/SUNWstade/lib/Discover/COMMON.pm /opt/SUNWstade/lib/Discover/D2.pm /opt/SUNWstade/lib/Discover/HBAApi.pm /opt/SUNWstade/lib/Discover/Inrange.pm /opt/SUNWstade/lib/Discover/Luxadm.pm /opt/SUNWstade/lib/Discover/QLOGICSW.pm /opt/SUNWstade/lib/Discover/SAMFS.pm /opt/SUNWstade/lib/Discover/SE.pm /opt/SUNWstade/lib/Email.pm /opt/SUNWstade/lib/FCRules.pm /opt/SUNWstade/lib/FCRules/Rule3.pm /opt/SUNWstade/lib/FSA.pm /opt/SUNWstade/lib/FSA/POLICIES.pm /opt/SUNWstade/lib/GUI/DumpConfig.pm /opt/SUNWstade/lib/GUI/Login.pm /opt/SUNWstade/lib/GUI/Review.pm /opt/SUNWstade/lib/GUI/Revision.pm /opt/SUNWstade/lib/GUI/UrlLaunch.pm /opt/SUNWstade/lib/GUIAdmin/3310.pm /opt/SUNWstade/lib/GUIAdmin/3320.pm /opt/SUNWstade/lib/HBAApi.pm /opt/SUNWstade/lib/Health.pm /opt/SUNWstade/lib/Health/3310.pm /opt/SUNWstade/lib/Health/5210.pm /opt/SUNWstade/lib/Health/6130.pm /opt/SUNWstade/lib/Health/9900.pm /opt/SUNWstade/lib/Health/A3500FC.pm /opt/SUNWstade/lib/Health/A5K.pm /opt/SUNWstade/lib/Health/Brocade.pm /opt/SUNWstade/lib/Health/COMMON.pm /opt/SUNWstade/lib/Health/Catalog.pm /opt/SUNWstade/lib/Health/D2.pm /opt/SUNWstade/lib/Health/Domain.pm /opt/SUNWstade/lib/Health/HBAStorage.pm /opt/SUNWstade/lib/Health/HBASwitch.pm /opt/SUNWstade/lib/Health/Host.pm /opt/SUNWstade/lib/Health/Internal.pm /opt/SUNWstade/lib/Health/MCDATA.pm /opt/SUNWstade/lib/Health/Message.pm /opt/SUNWstade/lib/Health/QLOGICSW.pm /opt/SUNWstade/lib/Health/SAMFS.pm /opt/SUNWstade/lib/Health/SE_MODULE.pm /opt/SUNWstade/lib/Health/Server.pm /opt/SUNWstade/lib/Health/Switch.pm /opt/SUNWstade/lib/Health/Switch2.pm /opt/SUNWstade/lib/Health/T3.pm /opt/SUNWstade/lib/Health/TAPE.pm /opt/SUNWstade/lib/Health/V880DISK.pm /opt/SUNWstade/lib/Health/VE.pm /opt/SUNWstade/lib/Http.pm /opt/SUNWstade/lib/InstallVerify.pm /opt/SUNWstade/lib/Inventory.pm /opt/SUNWstade/lib/Java/Discovery.pm /opt/SUNWstade/lib/Java/JVM.pm /opt/SUNWstade/lib/Java/JavaDiags.pm /opt/SUNWstade/lib/Java/JavaObject.pm /opt/SUNWstade/lib/Java/JrexClient.pm /opt/SUNWstade/lib/Java/Report.pm /opt/SUNWstade/lib/Java/TreefrogControls.pm /opt/SUNWstade/lib/Java/WBEM.pm /opt/SUNWstade/lib/Linktest.pm /opt/SUNWstade/lib/Linktest/BROCADE.pm /opt/SUNWstade/lib/Linktest/HBA.pm /opt/SUNWstade/lib/Linktest/Node.pm /opt/SUNWstade/lib/Linktest/QLOGICSW.pm /opt/SUNWstade/lib/Linktest/SWITCH2.pm /opt/SUNWstade/lib/Logic/3310.pm /opt/SUNWstade/lib/Logic/5310.pm /opt/SUNWstade/lib/Logic/SE.pm /opt/SUNWstade/lib/Logic/SWITCH.pm /opt/SUNWstade/lib/Logic/Subnet.pm /opt/SUNWstade/lib/MG/T3.pm /opt/SUNWstade/lib/Mail.pm /opt/SUNWstade/lib/Map.pm /opt/SUNWstade/lib/Matrix.pm /opt/SUNWstade/lib/MaxEvents.pm /opt/SUNWstade/lib/NWS.pm /opt/SUNWstade/lib/NWS/3310.pm /opt/SUNWstade/lib/NWS/5210.pm /opt/SUNWstade/lib/NWS/A3500FC.pm /opt/SUNWstade/lib/NWS/COMMON.pm /opt/SUNWstade/lib/NWS/D2.pm /opt/SUNWstade/lib/NWS/DSP.pm /opt/SUNWstade/lib/NWS/Host.pm /opt/SUNWstade/lib/NWS/MCDATA.pm /opt/SUNWstade/lib/NWS/QLOGICSW.pm /opt/SUNWstade/lib/NWS/SE.pm /opt/SUNWstade/lib/NWS/STD_REPORT.pm /opt/SUNWstade/lib/NWS/T3.pm /opt/SUNWstade/lib/PDM.pm /opt/SUNWstade/lib/PDM/ConfigFile.pm /opt/SUNWstade/lib/PDM/Parse.pm /opt/SUNWstade/lib/PPRO.pm /opt/SUNWstade/lib/Perf.pm /opt/SUNWstade/lib/Policies.pm /opt/SUNWstade/lib/Process.pm /opt/SUNWstade/lib/Provider/Email.pm /opt/SUNWstade/lib/Provider/NSCC_Email.pm /opt/SUNWstade/lib/Provider/NetConnect.pm /opt/SUNWstade/lib/Provider/SAE.pm /opt/SUNWstade/lib/Provider/SSRR.pm /opt/SUNWstade/lib/Provider/SunMC.pm /opt/SUNWstade/lib/Provider/Trap.pm /opt/SUNWstade/lib/RasDB.pm /opt/SUNWstade/lib/Rasagent.pm /opt/SUNWstade/lib/Registration.pm /opt/SUNWstade/lib/Report.pm /opt/SUNWstade/lib/Reports.pm /opt/SUNWstade/lib/Reports/Event.pm /opt/SUNWstade/lib/Revision.pm /opt/SUNWstade/lib/Revision/3320.pm /opt/SUNWstade/lib/Revision/3511.pm /opt/SUNWstade/lib/Revision/5210.pm /opt/SUNWstade/lib/Revision/5310.pm /opt/SUNWstade/lib/Revision/6120.pm /opt/SUNWstade/lib/Revision/A3500.pm /opt/SUNWstade/lib/Revision/A5K.pm /opt/SUNWstade/lib/Revision/COMMON.pm /opt/SUNWstade/lib/Revision/D2.pm /opt/SUNWstade/lib/Revision/FC_DISK.pm /opt/SUNWstade/lib/Revision/HBA.pm /opt/SUNWstade/lib/Revision/MCDATA.pm /opt/SUNWstade/lib/Revision/QLOGICSW.pm /opt/SUNWstade/lib/Revision/SAMFS.pm /opt/SUNWstade/lib/Revision/SilkWorm.pm /opt/SUNWstade/lib/Revision/T3.pm /opt/SUNWstade/lib/Revision/TAPE.pm /opt/SUNWstade/lib/Revision/V880DISK.pm /opt/SUNWstade/lib/Roles.pm /opt/SUNWstade/lib/SE.pm /opt/SUNWstade/lib/SO.pm /opt/SUNWstade/lib/SYMsdk.jar /opt/SUNWstade/lib/SYMsdk.v0912.jar /opt/SUNWstade/lib/Scheduler.pm /opt/SUNWstade/lib/Service/Upgrade.pm /opt/SUNWstade/lib/Slave.pm /opt/SUNWstade/lib/Snapshot.pm /opt/SUNWstade/lib/State.pm /opt/SUNWstade/lib/System.pm /opt/SUNWstade/lib/TO.pm /opt/SUNWstade/lib/TO/3310.pm /opt/SUNWstade/lib/TO/3320.pm /opt/SUNWstade/lib/TO/5210.pm /opt/SUNWstade/lib/TO/5310.pm /opt/SUNWstade/lib/TO/6130.pm /opt/SUNWstade/lib/TO/A3500FC.pm /opt/SUNWstade/lib/TO/A5K.pm /opt/SUNWstade/lib/TO/Applet.pm /opt/SUNWstade/lib/TO/BROCADE.pm /opt/SUNWstade/lib/TO/COMMON.pm /opt/SUNWstade/lib/TO/D2.pm /opt/SUNWstade/lib/TO/HBASTORAGE.pm /opt/SUNWstade/lib/TO/HOST.pm /opt/SUNWstade/lib/TO/Node.pm /opt/SUNWstade/lib/TO/QLOGICSW.pm /opt/SUNWstade/lib/TO/SE.pm /opt/SUNWstade/lib/TO/SE2.pm /opt/SUNWstade/lib/TO/STORAGE.pm /opt/SUNWstade/lib/TO/T3.pm /opt/SUNWstade/lib/TO/TAPE.pm /opt/SUNWstade/lib/Tests.pm /opt/SUNWstade/lib/Tests/3510.pm /opt/SUNWstade/lib/Tests/3511.pm /opt/SUNWstade/lib/Tests/Brocade.pm /opt/SUNWstade/lib/Tests/QLC.pm /opt/SUNWstade/lib/Tests/QlogicSwitch.pm /opt/SUNWstade/lib/Thresholds.pm /opt/SUNWstade/lib/Transition.pm /opt/SUNWstade/lib/Trap/5210.pm /opt/SUNWstade/lib/Trap/5310.pm /opt/SUNWstade/lib/Util.pm /opt/SUNWstade/lib/Util/Http.pm /opt/SUNWstade/lib/auto/Crypt/Blowfish/Blowfish.dll /opt/SUNWstade/lib/auto/Crypt/Blowfish/libBlowfish.dll.a /opt/SUNWstade/lib/auto/Crypt/MD5/MD5.dll /opt/SUNWstade/lib/auto/Crypt/MD5/libMD5.dll.a /opt/SUNWstade/lib/auto/FCGI/FCGI.dll /opt/SUNWstade/lib/auto/FCGI/libFCGI.dll.a /opt/SUNWstade/lib/auto/XML/LibXML/Common/Common.dll /opt/SUNWstade/lib/auto/XML/LibXML/Common/libCommon.dll.a /opt/SUNWstade/lib/auto/XML/LibXML/LibXML.dll /opt/SUNWstade/lib/auto/XML/LibXML/libLibXML.dll.a /opt/SUNWstade/lib/auto/wget/COPYING /opt/SUNWstade/lib/auto/wget/wget-1.8.2.tar.gz /opt/SUNWstade/lib/bsh.jar /opt/SUNWstade/lib/httpstransport.jar /opt/SUNWstade/lib/storade.jar /opt/SUNWstade/lib/storade_device.jar /opt/SUNWstade/lib/trustedcerts /opt/SUNWstade/libxml2/lib/libgcc_s.so.1 /opt/SUNWstade/libxml2/lib/libiconv.so.2 /opt/SUNWstade/man/man1m/6120ondg.1m /opt/SUNWstade/man/man1m/6120volverify.1m /opt/SUNWstade/man/man1m/checkcron.1m /opt/SUNWstade/man/man1m/clearcache.1m /opt/SUNWstade/man/man1m/config_solution.1m /opt/SUNWstade/man/man1m/echotest3510.1m /opt/SUNWstade/man/man1m/echotest3511.1m /opt/SUNWstade/man/man1m/emlxtest.1m /opt/SUNWstade/man/man1m/loopmap3510.1m /opt/SUNWstade/man/man1m/loopmap3511.1m /opt/SUNWstade/man/man1m/looptest3510.1m /opt/SUNWstade/man/man1m/looptest3511.1m /opt/SUNWstade/man/man1m/qlctest.1m /opt/SUNWstade/man/man1m/ras_admin.1m /opt/SUNWstade/man/man1m/ras_discover.1m /opt/SUNWstade/man/man1m/ras_install.1m /opt/SUNWstade/man/man1m/ras_patchlist.1m /opt/SUNWstade/man/man1m/ras_remote.1m /opt/SUNWstade/man/man1m/ras_revcheck.1m /opt/SUNWstade/man/man1m/ras_upgrade.1m /opt/SUNWstade/man/man1m/rasagent.1m /opt/SUNWstade/man/man1m/sanbox.1m /opt/SUNWstade/man/man1m/save_password.1m /opt/SUNWstade/man/man1m/showBypassDevice3510.1m /opt/SUNWstade/man/man1m/showBypassDevice3511.1m /opt/SUNWstade/man/man1m/showBypassSfp3510.1m /opt/SUNWstade/man/man1m/showBypassSfp3511.1m /opt/SUNWstade/man/man1m/t3command.1m /opt/SUNWstade/man/man1m/t3volverify.1m /opt/SUNWstade/man/man1m/wrbtest3510.1m /opt/SUNWstade/man/man1m/wrbtest3511.1m /opt/SUNWstade/nscc/secureEmail.pl /opt/SUNWstade/rasagent.conf.mk /opt/SUNWstade/rasserv/bin/apachectl /opt/SUNWstade/rasserv/bin/restart /opt/SUNWstade/rasserv/libexec/libcrypto.so.0.9.7 /opt/SUNWstade/rasserv/libexec/libgcc_s.so.1 /opt/SUNWstade/rasserv/libexec/libssl.so /opt/SUNWstade/rasserv/libexec/libssl.so.0.9.7 /opt/SUNWstade/sbin/allqlogicswitchzones /opt/SUNWstade/sbin/archivejob /opt/SUNWstade/sbin/bcrypt /opt/SUNWstade/sbin/brocadezone /opt/SUNWstade/sbin/dev_ip /opt/SUNWstade/sbin/dis_devinfo /opt/SUNWstade/sbin/dis_hba /opt/SUNWstade/sbin/dis_luxadm /opt/SUNWstade/sbin/emlxinfo /opt/SUNWstade/sbin/emlxtest /opt/SUNWstade/sbin/gpg /opt/SUNWstade/sbin/https_transfer /opt/SUNWstade/sbin/qlogicSwitchPortType /opt/SUNWstade/sbin/qlogicadminstate /opt/SUNWstade/sbin/qlogiccounters /opt/SUNWstade/sbin/qlogicswitchzones /opt/SUNWstade/sbin/readToc /opt/SUNWstade/sbin/relocate /opt/SUNWstade/sbin/run_perl /opt/SUNWstade/sbin/run_perld /opt/SUNWstade/sbin/srs_send /opt/SUNWstade/sbin/volverify /opt/SUNWstade/snmp/share/snmp/mibs/se5210_1.mib /opt/SUNWstade/snmp/share/snmp/mibs/se5310_1.mib /opt/SUNWstade/snmp/share/snmp/mibs/se5310c_1.mib /usr/lib/libqsw.so Problem Description: ------------------- 6346603 CRC errors in Storade, no events in 3510 6345248 WH1.0b08,10:Revision Analysis report of HBA patches displays a 4Gb HBA on the host as 2Gb HBA 6338483 cannot discover devices from slaves: Connection refused(security turned on) 6328807 (2.3)array_policies RAS policies 27 and 28 both severity informational 6326366 McData agent should use IP/IPNO consistently 6322839 (2.3)RAS MSGS: sa2.[34]: The RAS messages from BEFIT are not included in the EGrid files 6314636 Spelling errors in T3/6120 6314616 change T3 to array in volume verify failed diagnostic message 6314284 Rev Check & Stresstest: From: email address is incorrect 6313662 Slave is still being monitored by master even if it has been deactivated as a slave 6313501 Agent Edit - 3320 in Categories to Monitor should be Sun 3320 6312331 (2.3)array_policies 27 and 28 never trigger 46 takes precedence by order of file policies 6312294 (2.3)6020 3.2 firmware log message pattern - LOOP DOWN detected policy 11 6311903 SPL: SPL 6130 ?Back? button fails in Service Advisor 6310976 (2.3)StorADE not reporting array error message indicating need for disk fw upgrade, vols got unmount 6310587 (2.3)6020 array_policy 33 Disk Scrubber task still receiving Info event, severity=x 6310581 (2.3)6020 3.2 firmware log message pattern remove 'd' should be missing array_policy 23 6310579 (2.3)6020 3.2 firmware log message pattern - Device tree array_policy 104 6310574 (2.3)6020 3.2 firmware log message pattern - parity on stripe array_policy 711 6308361 vol verify job is terminated the end time is left blank 6306596 Recommended action for a change of status on a port (online) should be changed. 6305976 StorADE doesn't identify a failed login attempt into a QLogic SANbox2 switch. 6299559 5310: Rev Check: can't check disks with 8 characters in firmware 6246505 (2.3)NRI: StorADE does not phone home a LOOP UP event as either a beep or nobeep 6222690 Storade client interface, DeviceReportService.getDeviceSummary(null) returns inconsistent results. (from 117650-50) 6311880 cannot turn on monitoring of brocade switches on slave. 6311579 Provider: Trap: provider added using ras_admin not prestent in UI 6311560 5310: no report/last scan time available for device 6311166 Bad Event Code: 20.26.ERR_6120 6311113 ras_admin discover_deviceIP crash 6309077 Notification: CIM_ER Key field must have value! 6308593 qlogicadminstate CLI displays password on command line 6307821 SE6130 Service Advisor does not differentiate between adding expansion trays and new arrays. 6305963 StorADE mis-classifies a restored fibre connection as a major alarm instead of an event. 6303925 update text of the recommended action for se2 events 6301718 Brocade agent should use IP/IPNO consistently 6300170 3510: diags: show_loopmap: formatting is difficult to read 6298957 Event Code: 19.26.ERR_t3 from se. 6298952 Event Code: 19.26.ERR_ve from se 6298949 Event Code: 19.26.ERR_switch received on latest code coming from se. 6298454 6130: Event 48.5.263 description needs update. 6297525 Can't use string ("x") as a HASH ref while "strict refs" in use at /opt/SUNWstade/lib/Java/Report.pm 6297466 Administration: not able to edit existing email 6297014 qlogicsw reports Error for port coming online 6293476 3320 monitoring alarms- critical actionable alarm is not reported 6293438 3320 monitoring alarms- Major alarms for non-major events 6292949 6130: stresstest job status in summary page and detail does not match. 6287516 Qlogic 5200: Devices > Device Details > Test Setup 6284153 6130:AR: alarm review of Log Events(patch 50) 6276708 REV CHECK: SANbox1-8/Qlogic 1g switch FW has patch listed for "PASS" FW 6267412 Revision Check detection of unsupported drives should be Informational 6250790 u1b5 - Service Advisor: inconsistency in calling for reservation of an 6130 array for maintenance. 6250240 sig1.2b5:6130: Service Advisor: status of removed drive slot is not "Other" 6241880 6130: sig1.2b4, Revision Checking Report: the expected patch not valid for s10 system 6227289 ras_admin provider_on nscc_email - add enable/disable encryption 6178890 (5089234) 6130: Pull interconnect cable between CRM-F and IOM but IOM still displays status of OK. 5066223 ras_install program does not apply defaults (from 117650-45) 6288899 Monitoring Skipping because of diagnostic conflict due to local linktest scripts running 6286820 Can't call method "type" on unblessed reference at /opt/SUNWstade/lib/TO.pm line 1011 6286744 SE6130 is reporting bogus FRU install alerts to the customer when no such action is in progress 6286339 6130 I/O diagnostics - stresstest 6285522 6130:AR:50: MEL 2255 is not used but the description is showing up in health.xml as 2252 6284859 StorADE does not detect an SE3310 Battery Backup Unit entering Thermal Shutdown/Sleep mode. 6284835 When SunMC provider is disabled then enabled, last.sunmc.topo file is not removed 6284177 6130:AR: MEL 2251 appears twice in health.xml 6283413 Provider: nscc_email sending empty Toc files when 0 events 6282743 patch 115360-04 should be 115360-05 for brocade switches 6279787 Single event (controller failure) generated multiple critical alarms. 6278806 Need to update matrix for patch 114476-05 6275590 SunMC notification limited to actionable alarms only 6274761 sccli output inconsistent. 6274753 5210: StorADE not discovering audi with FW 4.5.0.14 6273735 Storade Install message doesn't have enough information 6273393 3310 StorADE reports the status of added EMU FRU as "NA". 6273339 The world "serial" is mis-spelled in the Probable Cause section of a generated event. 6271978 unmonitored slaves still sending events 6266257 StorADE CLI does not support change in agent polling frequency 6264529 storade is leaving a file called ras_bad_modules.info in /tmp 6255912 SUNWstade on datahost send event 30.20.ERR when SIO pulled on dsp 6254862 Device Discovery: Status on summary and detail ui pages not matching. 6253280 switch2: Power failure No alarm displayed 6250099 1.2b5:"Export configuration doesn't contain information on the 6130s" 6247437 (6258073) 3510 critical error email generated although no fault inject 6241090 rev check: output needs to show more 6235771 6130: rev check: no patch information available - Need patch # 6210820 RR: Unity 3.0: rasagent should first ping rack before continue se2 agent module tasks 5100487 Informational email about discovery different for most devices 5050631 M2b19 : Step 6 in "Adding Storage Array" has cabinet release conflict 6239831 BETA: Service Advisor tree resets to top on each arrow click 6270508 (sepkg)prewaring message and auto detection are necessary to avoid found situation. (from 117650-39) 6271722 NSCC: se2.AuditEvent not received. 6269308 T3A reports Invalid Field in CDB with StorADE 2.4 6267953 Inband device showing loss of communication alarm 6267808 not able to check revison for ST336753FSUN36G in 6120 storage array 6267241 NRI: dummy-disabled disks are a warning event during initial discovery of an array. 6265662 sys_error Cannot identify this 9900 6265636 TO/SE.pm returns wrong number of ports sometimes 6265274 3510 The word assistance is mis-spelled in the recommended action section of disk status alarm page. 6264392 Brocade agent times out once an a while 6264160 State of SE3510 Power supply (and other FRUs) listed as NA. 6262833 SE6130: StorADE unable to register the array when the management host uses a non standard netmask 6262281 u1b6 - StorADE fails to recognize new Fujitsu 15K RPM drives. 6261887 RSb2:Storade get devices call returns too many devices / some devices are corrupt 6260863 rasagent errors with Can't coerce array into hash at /opt/SUNWstade/lib/PDM.pm line 105 6259345 Event Code: 20.25.ERR_6020 from datahost monitoring rack after powering up hub in rack 6259327 Event Code: 20.26.ERR_6020 from datahost monitoring rack after powering down hub in rack 6259017 Logical Device in 5210 and 5310 shown as FRU.(NSCC bug 6246683) 6257363 3510 Recommended action for missing power supply not correct. 6256377 Revision Check: expected patch for upgrade is for current firmware 6255633 NRI: single OOB loss communication events should NOT be actionable; Need FSA 6255377 Remove ras_admin event_list, it is not documented nor implemented. 6254752 Update config matrix with new qlc5200 switch fw V4.0.2.04 6254179 various diags failing with sh: /opt/SUNWstade/Diags/bin/[diag] not found 6252686 Vol Verify failes on 3.2 T3B FW when run through Storade. 6251009 StorADE CLI does not support discovery of products with passwords 6250760 ras_admin host_delete failing 6248928 SUNWstade on datahost did not send a "repair" event after positive state change on SP hardware 6248912 Rev checking: UI/CLI give different results 6248889 v880 ses test: displays no output with or without verbose option selected 6248240 disk test Fails: device no longer seen by system(GUI) 6247428 3510 topology is incorrect 6246921 NRI: StorADE lists creation of global spare as a critical event 6246022 5310: disk removal not detected 6245498 1.2b4: 6130SupportData lists the Drive Type for SATA drives as Fibre 6245385 1.2b4:Storade doesn't list all of the logical components for a slave/master. 6245164 ras_install prompting for removal of core file rm: core: 6244536 1.2b4:Users not prompted to set up "Update Monitoring & Setup Info" before running 6130SupportData 6244533 T3: event 13.3.56 needs rewording. 6244036 Qlogic: Older version of storade link in event 53.5.7 RA 6244035 6130: 6130SupportData can not find array with Fully qualified DNS identifier. 6243853 Inrange: Older version of storade link in event 31.5.7 RA 6243844 HOST: Error in event 7.5.20 RA 6243805 6120: Error in event 21.12.31 RA 6243794 9900: wrong instruction in event 27.12.31 RA 6243790 d2 rev check: Sun D2 Disk FW needs patch info 6243777 token default time out setting not correct for event 13.12.31 RA. 6243757 replace in several EGrid files StorADE with Storage A.D.E 6243724 event 3.41.13 needs pc 6243722 a3500fc rev check: firmware rev patch info needed 6243677 Invalid Setup. message should include "run ras_install" 6243638 StorADE 2.4 bundle for NC3.2 does not include the release notes 6243140 se2.ComponentRemoveEvent: slot.3 not in Event Log no email notification received 6243104 error in T3test usage 6242419 NRI: 6130 : componentInsert event 48.40.251 severity should be information. 6242368 switch2: Event Code: 12.5.9 change to Crit/Actionable 6242339 Mcdata: mcdata.ValueChangeEvent DESCRIPTION 6242338 Mcdata: Event aggregation wrong root cause 6242200 NRI: t3 : 13.40.13 ComponentInsertEvent Event should be info 6241804 5310 Revision Checking not checking for OS or controller bios 6241267 NRI: 5210: Critical ComponentRemoveEvent should be warning 6239493 6320: Devices > Device Details > Logical Component Summary: incorrect slice count 6238435 3510: event needs pc, ra and event code in bui 6236409 NRI: 5210 Power supply removal needs to be major not 4 6235777 6120 Email/UI event mismatch in severity 6235703 RR: Log events left on rack appear to cause datahost to not send latest info 6235701 RR: E-mails from datahost monitoring rack did not show correct repair info from R/R'ing a loopcard 6235630 3910: se_configcheck 6234587 RR: Unity3.0: toplogy includes non-existing hubs 6233820 NRI: T3: UI alarm severity doesn't match email alert - both should be the same 6226893 ESM: The storade Client Infc sends alarms w/o timestamp 6225757 NRI: Email provider nscc_email taking excessive time with encryption turned on 6224261 RR: Unity3.0: SFC - component insert event not detected, severity major 6224121 BETA: U3.0: se2 component remove events severity Major doesn't match FSA critical severity on rack 6219119 (6219113) 5210/5310 Logical volume count incorrect 6219100 (6218565)5210 logical drive STATE/STATUS is unknown 6208592 sccli shutdown command syntax incosistent between SE3511 and SE3510 6207732 T3: Battery failed not triggering UI power supply alarm 6205989 Uninstall of StorADE2.4 on Solaris 10 leaves behind /opt/SUNWstade/DATA directory 6201851 T3: CIM_ER Invalid Type for CIM_MediaPresent->Dependent 6188995 2 possible typo in OLH 6186095 9900 monitoring needs to be refined. 5103529 5210 EVENT CODE incorrect 47.5.ERR_RaidSystemDriveCachePolicy 5102761 Rev Check Report format gives errors for devices not the storade config 5097868 ras_install fails without XML pkgs installed 4973820 ras_snap message displayed in Provider Trap of rasagent output with the depkg 4948042 Monitor->Diagnose->Test "Warning: A test is running on 0x301.5016338.400176" 6201699 Webconsole: Adding unicode username to acknowledge form - empty alarm list 6220129 Junk and obsolete files files are installed by the base packages 6233330 The Shark.so link is not removed when the 2.4.21.007 package or 1176541-11b patch is removed. (from 117650-35) 6243154 6130: extra word in event 48.20.319 PC 6232290 GUI should indicate user is on the slave (from 117650-34) 6244993 rasagent coredumping 6238096 SE6130: StorADE : Remove logging to /var/adm/messages.6130 6237846 6130: Revision Check : Not getting revision information for 146G Fujitsu Drive. 6237820 NRI: Switch ports offlined by admin should not be critical 6237076 disktest usage spelling error 6236757 High Security Alert: non encrypted passwords in explorer data file 6236307 Discovery: Subnet discovery not adding ip addresses to conf file 6235888 5210: Revision Checking not comparing current to expected version 6235644 Mcdata Event code 17.5.19 needs additional PC. 6235641 mcdata: incorrect detection of Fan fault 6235616 abbreviations.txt: 3600/6900 needs to be 3900/6900 6235605 HDS: Loss comm event severity incorrect 6234639 6130: Revision Checking : wrong status for 146G Hitachi drive 6234569 Brocade: Sensor information missing 6234504 3511: recieved 2 events for one controller pull 6234430 NRI: qlogic 1G : Admin onlining an offline port caused critical/actionable 6234343 minnow: devices with inband path will not alarm on lost oob comm 6234026 switch2 event switch2.ValueChangeEvent DESCRIPTION 6233955 STP: Host storage - Components Summary has incorrect/inconsistent information - WWN 6232724 NRI: map files fail to recognize state if a space comes aftert the last character on the line 6231443 5210/5310: FRU: External UPS count incorrect 6230572 6130: Blank property name in system parameter page. 6227918 BETA:No event received from datahost monitoring rack indicating positive state change after repair 6227827 Brocade: SNMP timeout causing loss of communication 6220338 StorADE 2.4 Enterprise Edition does not forward se2 alarms to SunMC 6219107 (6220831) 5210/5310 JBOD fan speed unknown 6210245 Device details page display banner when not monitoring device 6207850 1.1b4:"addShutdownHook(Ljava/lang/Thread;)V" not found err while running diagnostics thru stade 5089518 interactive applet topo doesn't distinguish fc & scsi attachments 5088820 (5089234) 6130: IOM.sfp disappear from FRUs summary page after removal. 4869154 don't change the status of KILLED to DONE in volverify only go to start or X (from 117650-33) 6232933 A5k disk slot count not decreased 6232283 Discovery: Error output at end of discovery message 6226712 BETA: Unable to create notification Filters 5074484 I18N: better not to allow saving l10n characters in Site Information fields (from 117650-32) 6226826 Remove stadm message at end of ras_install if pkg is installed 6226337 Communication loss with Slave: cause incorrect 6224790 Jobs: a5ksestest fails to register completion 6224750 sun-switch missing port state/status 6178861 6130: Controller Detail always displays FC Port - Raw Status as "UNKNOWN". This should be defined. (from 117650-31) 6225221 Device Instrumentation being skipped 6224084 Additional SupportData information from the "statecapture" request 6224004 QuiesceEndEvent INFORMATION 6220130 1.1b4:Inconsistency between between 6130SupportData and santicity output 6218992 No error when agent errors cause the agent to "shut down permanently" 6215302 Storade client interface, DeviceSummary.getCategory() returns null for treefrog elements. 6201830 Testmail.pm and Mail.pm do not use correct smtp syntax - this may result in failed notifications 6198720 Config-matrix: Update for t3 and 6120 firmware 5105119 T3 Event Code: 13.41.37 needs PC (from 117650-30) 6214281 port State Events time can be very unfriendly 6214268 term StorADE in /var/adm/messages 6213753 discovery: devices not added on private net - COMMON::6130 ... ->HASH(0x19ab4a8) 6213749 discovery: JVM used for treefrog isn't getting started on private net 6211831 Diags: UI not passing IP address to Sun-2_gig_Switch diag test 6211766 ras_admin email_list: add active state yes/no 6211324 McData: update TOC file to include revision and version information 6209604 ras_install: does not run on solaris 10: /opt/SUNWstadh/dhbin: does not exist 6206059 1.1,b4:6130 SATA drive firmware status is displayed as "DOWNREV" even though the firmware is at b4. 6206051 Configuration report not showing installed patch. 6206042 Host ID in configuration report is incorrect. 6206025 Event Code: ERR_TOTAL-hbaswitch.20.313 for MPXIO event 6206014 6130: Not getting Fan component removal event. 6203429 patchinfo does not include all supported os's 6202140 6130: Topology still show Host FC connection to 6130 even after FC cable was removed. 6202066 6130: Diagnostic status not updated when run on an alternate master. 6201931 Add sense/Asc/Ascq codes to the entries in the event log 6201928 a5000: UI Event info incomplete/ 6201902 a5000: UI components summary incorrect 6201806 ras_install Empty Master creates different rasagent.conf file 6199419 ras_install on hosts with no HBA's returns message that HBA APi packages are not installed 6198978 6130: block 6130 diag tests if qlc/jni test is running 6198977 brocade: block brocade switch test if qlc/jni test is running 6198837 6130: SATA : typo in event 48.5.432 6198728 Topology: fiber hub showing in topo 6196767 ras_install: Unknown option: I 6196703 snmpwalk System error alarm on host in storade (New 5200 switch) 6196385 Service Advisor: Removing Storage Arrays--Needs steps/reference to handle vertical volumes. 6194312 100f all nscc rcvd events were repeated voloper normal going change events 6194263 Vol verify state changes for t3 6020 and 6120 are too noisy 6193799 excessive noisy events due to system error events generated by storade 6193443 StorADE 2.4 ras_install instructions point the user to the browser when only the CLI pkg is installe 6192320 Storade patch and Storade L10N patch need to remove Storade during re-register processes 6186220 D2 NSCC FRU report Power supply FRU state empty 6186216 D2 NSCC Revision, Version, SN missing main device page 6186215 D2 NSCC Alarms not in Alarms/Events report 6186099 6130: IOM Details page displays RLS counter but these counters are not working properly. 6184847 6130: device name not updated after changing device name in EM 6183904 6130: NVSRAM upgrade is not detected by StorADE. 6182538 volCacheMode and volCacheMirror in disabled state are Information msgs at START 6180517 false QuiesceEndEvent when Update Monitoring and Setup information saved 6179421 RR: se2_configcheck start and end times are reversed 6179191 discovery continues refresh after job completed 6178520 Framework doesn't support Catalog as defined in Device Starter Kit API 5103875 Failure message for IOM should include FW download as a RECOMMENDED-ACTION 5102676 T3 PCU Fan Failure Grid Code: 13.26.37 5100301 6130: Pulled one ethernet cable, no event or alarms from StorADE. 5098166 (5089234) 6130: statechange event not using element name. 5086797 6130: RawStatus not used when a disk is removed in disk FRU summary page. 5038576 a3500fc: disk removal displayed twice in nscc. StorADE is sending multiple evts 5019073 ISP2300[2] messages are front-end I/O and need their own grid number 4891682 NSCC: change the nscc encrypted email provider to default encrypted 4888004 erraneous path between HBA & 6320 rack displayed in topology 4834213 Devices show On/Off for status after turning a Slave into Master 4830507 Run Agent status is not available if you leave the Run Agent screen (from 117650-15 to 117650-29) (from 117650-14) 6238299 Change HITACHI HDS7240SBSUN400G expected revision to KFA9A47A 6219062 rasagent segmentation Bus Error(coredump) fault when running nscc provider 6213768 117650-12 does not install on solaris 10 s10_73 6202601 3310: event 18.5.227 differ in bui and email 6202088 3310: event 44.5.19 differ in bui and email 6202020 minnow raid: event 18.41.270 ra does not need to include 30 minute message 6201208 3511: Event Code: 4.12.31 used array name instead of logical drive name 6201149 3511: Event Code: 45.20.313 needs pc and bui and email alerts differ 6201135 3511: bui and email alerts differ 5102073 (5102064) 3310raid: lost comm event after manual fail of primaray controller 5099682 3510: diag tests display PASS 1 of 1 reguarless of passes requested 5073925 (5014422) 3511: false power supply ComponentInsertEvent's 5066214 (4889967) 3X1X log events from previous months show up as new event 5044750 3510: test in progress gives key name rather than device name 5027700 (5023653 and 4812759) 3510: Controller Shutdown status not displayed in GUI Summ 5023420 minnow: reduce 3310 agent run time (from 117650-13) 6213187 StorADE 2.4 cannot run ras_install with -n option for NetConnect config (from 117650-12) 6197980 Add mapping data to SupportData collection 6197426 6130 Detect uncertified drives 6197325 able to run multiple diags at once 6196832 3120: bui alert and email alert differ 6196693 6130: SATA : negative value in midplane property. 6196603 Request addition of the sense/ASC/ASCQ codes to the SupportData bundle 6195986 add "Add Email Notification type: Pager function" to ras_admin cli 6195945 Need to be able to see which is monitoring host at all times 6192388 6130 - A failed tray was reported as "fan removed" by Storade. 6192123 Release Notes for SUNWstade and SUNWstadm 2.4.12.007 indicate 2.4.11.005 6191468 6130: Offline Controller causes Battery Removal to become top level alarm. Same for controller pull. 6190764 3310: Device Details (detailed view) > Components section show FRU section information 6189655 Release notes need update for SAM-QFS 6189577 Service Advisor does not exactly match LH2.2 look and feel 6189030 Vol Verify jobs on slave not displaying in jobs report in UI 6188967 3310jbod: event 44.41.271 needs pc 6188818 discovery: prefix agent name not working with All Agents selected 6184908 6130: disk drive removal cause CRITICAL alarms. This should be major or lower. 6184660 T3: t3.ComponentRemoveEvent when vol mounted. 6184617 6130:IOException in error message when directory does not exist for 6130SupportData command 6184598 6130: code displayed in error message for 6130SupportData command 6184149 6130: SFP Removal should not be CRITICAL/ACTIONABLE. 6183684 Sevice Advisor - Labels of some links are different from the destination page title. 6181904 Mcdata comm loss causes long agent run 5110119 Jobs Summary report is incomplete 5109657 Qlogic switch property values not localizable. 5107117 ras_admin site_info_upd does not contain same fields as GUI screen 5107115 ras_admin email_add does not allow user to select priority/components 5103207 the transition from fault to notInstalled/missing is generating an actionable ev 5100373 Local Notification Gui does not allow pager notification 5091436 3310jbod: no alert at topology 5088114 (5062281) SAM-QFS Dependent Tape Drive / Library loss of comm not detected 5074386 ras_admin provider_on -p netconnect 5073858 (5079613) 5210 incorrect disk reported in trap logs 5066803 Release Notes for patch 116720-08a needs 5210 info 5050444 3120jbod: 3 alarms for one event should be 1 alarm and 2 sub-events 5025953 3510: echo_test: limit channel selection to connected channels 5024844 man pages reference obsolete "User's Guide" instead of the GSG 5015076 3510: StorADE is not displaying inter-controller-link status. 4633337 Don't allow password to be cached in browser (from 117650-11) 6194487 I18N: Properties are not l10ned on System Parameter page of some Devices 6189010 Install of SUNWstadm fails, Startup failed: cannot assume user identity "noaccess" 6188969 able to run multiple diags at once 6188884 qlogic reports sys reboot event after 497 days ref CR 5109535 6186248 6130: Event 48.20.353 RA state "Check the status of cables" but cable status is not available. 6185548 ras_admin email setup does not provide for entering SMTP server information 6184915 Need a complete audit of devices to occur after enabling NetConnect/SSRR/NSCC notification providers 6184884 6130: "&" char in device name break discovery. 6184593 6130: Event 48.5.262 - Drive.1.nonRedundantAccess should have additional PC and RA. 6184579 The disk position provided in the Audit does not match the position given in other events 6184548 6130: Tray 11, Disk 1 failed, but Alarm Summary displays Component as "disk.8". 6184142 6130: Pulled IOM but SFP removal is top level alarm. IOM removal should be top level alarm. 6183949 On image storade/service/en/images/23702.gif, the numbers 2 and 3 not refer to right objects 6183944 In the 3120jbod.grid and 3310jbod.grid, some numbers seem not correct 6183880 6130: Aggregated Firmware upgrade event not displayed on StorADE event log page. 6183836 6130: Add "6130 Firmware Upgrade" to PC for event code 7.20.315 - driver.QLC_LOOP_OFFLINE. 6183685 Sevice Advisor - Links are without the underline on "Removing a Storage Array" page. 6183473 "=" is missing from key "fruDiskPort2StateDisk Port2 State" in t3_resources.properties 6183366 converting slave to master not handled well 6183068 FRU inventory can not be generated on Service Advisor. 6182898 rashttp proccess runs at a default priority that is too high 6182182 Authentication with old client storade.jar failes. 6182025 D2 Power supply count doesn't change when removed 6181927 Need to change the version of the storade_pvr from 2.3 to 2.4 6181229 Connect to hostname:6789 failed 6176518 6130: While volume assigned to ctrlA, pulled cable from ctrlB, SA did not detect link status change. 5109535 StorADE reported McDATA 4500 uptime decreased from 49 days 16:41:42.50 to 0:04:17.12 5107606 command line only installation and configuration 5105156 description in all valueChangeEvent (formerly alarmEvent) are all blank 5104243 Webconsole: Interactive topology applet - selecting 'Layout wizard' cause logout when diff domains 5103763 b10: Stade IP discovery does not allow blank space or between IPs 5103463 b10: javax.servlet.ServletException when acknowledge alarms 5103327 job details always shows Status: Not running 5102580 storade needs to upgrade to openssl 0.9.7d 5102485 3511: populate channel state and status 5100352 config matrix update 5099703 Change HBA Switch to Inband Switch 5099545 3510: change error when password is not provided 5099498 3510: no logical drives listed 5099071 minnow scsi: use fru_status to populate Fru Status field 5098542 Interprocess communication has a potential security problem. 5098095 event grid type not matching in 6130.grid for iom 5097874 SUNWstadm postinstall script gives no pointer to login information 5096864 6920 LUN Logical Components listing deleted volumes 5091403 3310 Device Details modifications 5091379 minnow: IP discovered do not recieve array name 5090749 3x00: use channel speed to indicate state in Device Details screen 5090075 Communication regain event from alternate master takes 1 hour. 5089074 Minnow: Need Insert and Delete events for volume changes 5089073 T3: Need Insert and Delete events for volume changes 5088800 Alarm Details: Recommended Actions: check for run away sentences and punctuation 5087566 /var/adm/messages: invalid Event code 7.20.ERR_driver.SD_ALERT 5086897 hba - FRU Summary level should include device path 5086674 ras_admin switch_add not working on slave 5083977 3310: actionable alert without alarm notification 5082221 Cannot configure as a master after configuring as slave (or alternate master ) 5077331 NSCC: D2 Power Supply/Disks/Fan FRUs data is missing. 5076817 change the ras_admin verbage about the agent to be consistent with UI - activate 5069469 5210 change headings under device summary > disks 5069458 5210 Add JBOD heading Device report 5059365 Stop unneccessary master to slave communication 5049834 minnow: include 'upper' or 'lowwer' in battery board fault events 5047042 3511_SATA_MUX_FW: rev check: error:no patch information available 5046998 3511: missing battery also generates power supply location change warning 5042776 3310jbod: 44.3.ERR_location: incorrect event for fault 5042759 3310jbod: summary report: need fields for emu's 5041540 3310: 3310.ValueChangeEvent/fru.1-9: cannot determine fru 5024702 minnow: 3x10.StateChangeEvent-lun: check for shutdown controller 5020713 3510: Please add channel mode to Device Summary Report. 5020701 3310: rediscovered OOB array in-band, still has OOB name. 4956081 SUNWeras should be a seperate pkg from SUNWstade 4872593 3510 fru table should include column for Status in the device report 4632868 Topology view of a5k should reverse interface board locations 4528540 Request message to user from alt master indicating rack cannot be monitored 5010374 Should give out warning info if user run diag function before topology snapshot (from 117650-01 to 117650-10) Known, Unresolved Problems: -------------------------- o 6290472 (6240910/6286138) StorADE error description and recommended action incorrect for the reported error Special Notes: -------------- o Please refer to the Storage Automated Diagnostic Environment Release Notes for additional installation, configuration, and usage information. The latest version can be found at: http://docs.sun.com/app/docs?q=819-0432 o Perl 5.005 through 5.8.3 is mandatory with the Storage Automated Diagnostic Environment product. Using version 5.8.4 and later has not been fully tested and may fail. o WARNING: Failure to upgrade the following devices to the minimum accepted firmware levels will result in failed discovery for the device. Sun StorEdge 3510 Controller f/w 411E SES 1046 or greater. Patch ID 113723-08 Sun StorEdge 3511 Controller f/w 411E SES 0413 or greater. Patch ID 113724-02 Sun StorEdge 3310 Controller f/w 411E SAF-TE 1168 or greater. Patch ID 113722-08 Before upgrading to Storage Automated Diagnostic Environment 2.4, any discovered SE3000 devices should be upgraded via the referenced patch. If StorEdge 3510 FC RAID, 3511 SATA, or 3310 SCSI RAID array are already discovered and found to be at a lower revision, monitoring of these devices will cease. To correct for this: o Delete the devices o Apply one or more of the patches mentioned above o Install this patch o Rediscover the devices o This Storage Automated Diagnostic Environment (Storage A.D.E) patch supports the Sun StorEdge 5210 NAS array with 3 optional attached StorEdge 5210 EU. - You must update your StorEdge 5210 NAS array to OS image version 4.3.0.16 or above in order to discover the array via Storage A.D.E. - Any StorEdge 5210 NAS array with an OS image version below 4.3.0.16 must be deleted from Storage A.D.E monitoring list. This patch will not support monitoring of StorEdge 5210 NAS array with OS image versions below 4.3.0.16. o Updating with this patch causes FRU removal/addition events Applying this patch may cause the application to report FRU removal and addition events for most FRUs in a 6130 array. This is due to a change in the decoding algorithm used to derive the serial number. This will occur as soon as the device is monitored with the new software and will show up as a single alarm with a large number of aggregated FRU removal and addition events. This alarm should be deleted and requires no other action. Patch Installation Instructions: -------------------------------- For Solaris 8-10 releases, refer to the man pages for instructions on using 'patchadd' and 'patchrm' scripts provided with Solaris. Any other special or non-generic installation instructions should be described below as special instructions. The following example installs a patch to a standalone machine: example# patchadd /var/spool/patch/117650-55 The following example removes a patch from a standalone system: example# patchrm 117650-55 For additional examples please see the appropriate man pages. Special Install Instructions: ----------------------------- o Installing this patch on Solaris 10 systems will fail during patchadd with the error message "wordlist too large" if Solaris 10 patch 119254-01 or later has not been installed on your system. See 6224767 Sun Java System Messaging Server patch fails with "wordlist too large" error 118207-27 If you encounter this problem during installation of this patch and didn't install the 119254 patch you will need to install patch 119254, remove this patch, and rerun the patch installation for this patch. o The permissions of the installation and backout scripts for in this patch are set to allow only the root user execute permission. This can impact users who extract this patch on on an NFS server and install it on their NFS clients. See 6242886 buildpatch creates patches that fail when installation is attempted on NFS clients If this patch is extracted locally you will not encounter a problem. If you extract this patch on an NFS server please refer to the suggested workarounds documented in 6242886. README -- Last modified date: Wednesday, December 7, 2005